A. Structure features:
1. With coal into gas combustion (intermediate), there is no smoke phenomenon, smoke depth for fifty - 70 mg, in order to achieve discharge standard.
2. Can save about 5% of fuel production, saving power consumption 10-30% or so, to achieve energy saving and consumption reduction.
3. A fuel available 30 - minutes, reduce the labor intensity of the operation, because of fewer fuel and working environment improved.
4. Because gas is flammable and explosive substances, so in the design of the increase in advance ignition device, as long as according to the operation procedures, like home with a gas (gas furnace) safe and reliable.
5. Fan can according to the requirements of customers, increase the frequency conversion adjustment control motor, the use of electricity to achieve the best effect.
6. The air supply system are equipped with the valve control, to ensure the operation period according to the user to use fire quantity requirements can be adjusted at any time.
7. In the grate at the bottom of the ash chamber increase water tank, which can realize the function of water safety. Still can make fall into the slag pool out, facilitate ash cleaning, because is wet ash discharge, no dust flying, operating environment and conditions are jotham step to improve.
8. Gas stove top with one or two dozen JiaoKong, convenient in the gas stove in the coking play coke.
2. Process
The system of the process is: will the combustion chamber lit stove, until after the flame appears to light gas stove - coal in the furnace internal peroxide, reduction, carbonization, after drying and air mixed gas - made into the combustion chamber - gas the furnace flame lit - began to burn.
Model
|
RMQ400
|
RMQ500
|
RMQ600
|
RMQ700
|
RMQ800
|
RMQ900
|
RMQ1000
|
Furnace inside diameter(mm)
|
400
|
500
|
600
|
700
|
800
|
900
|
1000
|
Furnace sectional area(㎡)
|
0.126
|
0.196
|
0.282
|
0.384
|
0.502
|
0.635
|
0.785
|
Water jacket hot area(㎡)
|
2.73
|
3.42
|
4.1
|
4.79
|
5.46
|
6.15
|
6.84
|
For coal
|
Don't bonding or weak bonding anthracite and bituminous coal or coke. Coal GB9143 should comply with the requirements
|
Ash layer height (mm)
|
100~200
|
100~200
|
100~200
|
100~200
|
100~200
|
100~200
|
100~200
|
Coal particle size(mm)
|
|
|
13~25
|
25~50
|
50~100
|
|
|
Coal consumption (kg/h)
|
10~20
|
30~40
|
50~60
|
70~80
|
90~100
|
120~140
|
150~180
|
Gas calorific value (Mm3/h)
|
30~60
|
90~120
|
100~180
|
210~240
|
270~300
|
360~420
|
450~540
|
Gas outlet temperature(KJ/m3)
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
5020~6060
|
Coal way manual (℃)
|
400~550
|
400~550
|
400~550
|
400~550
|
400~550
|
400~550
|
400~550
|
Coal way
|
manual
|
Fan motor power (kw)
|
2.2
|
2.2
|
3
|
3
|
4
|
5.5
|
7.5
|
Fan pressure(Pa)
|
1139
|
1139
|
1439
|
1439
|
1668
|
2491
|
2986
|
Fan flow(m/h)
|
1146
|
1146
|
1539
|
1539
|
2550
|
3212
|
5113
|
Discharge form
|
Wet, automatic discharge
|
|